Full Equipment Catalog
| Field Strength Meters |
| PI 4100 |
Covers 520 kHz to 5.1 MHz frequency spectrum, |
$ 14,975.00 |
| PI 4100 |
(Special Tuning) Covers 200 kHz to 5.1 Mhz frequency spectrum |
$ 15,475.00 |
Field Strength Meter Accessories
|
1440 Hard Case for PI 4100 meter
AC-4100 117/230 VAC Charging supply for PI 4100 |
$385.00
$ 70.00 |
| EPG-1068NiMH Battery Pack for PI 4100 |
$ 75.00 |
| LM10540 Battery tray for PI 4100 allows use with single use AA batteries |
$ 15.00 |
| LM10541 Charging Cable for Vehicle use (Cigarette Lighter cord) |
$ 25.00 |
| LM10529 Die Cut Foam Set for Pelican 1610 (fits PI 4100) |
$ 80.00 |
| HS-11 Headset for all models |
$ 40.00 |
| SOFT CASE Padded Soft Carrying Case for FIM series meters |
$ 210.00 |
| |
Made of 400 denier Pack Cloth. Suitable for all Potomac
Field Intensity Meters. (Please specify meter to be carried.) |
|
| UNIPOD Telescoping stand for all models. |
$ 145.00 |
| ANT-71 Calibrated VHF Dipole Antennna
(spare) for FIM 71 |
$ 2,075.00 |
| |
Replacement Antenna Element (AE-71)
for ANT-71 |
$ 50.00 |
| ANT-72 Calibrated UHF Dipole
Antenna (spare) for FIM-72A |
$ 2,795.00 |
| AC-72 117/230 VAC Adaptor for FIM-71, FIM-72 |
"Special Order Item" |
| RO-71 Phone plug |
$ 210.00 |
| |
with internal potentiometer for adjustable record output
for all models. |
|
Test Cables for
use with FIM-71 and FIM-72A |
| B20145-4 44 in. Coax Test Cable, RG-223 |
$ 75.00 |
| B21045-5 34 ft. Coax Test Cable, RG-223 |
$ 165.00 |
to index...
| Tower Light Monitor |
| 1750 TLM Tower
Light Monitor: |
$ 940.00 |
| |
4 Channel "Stand-alone" module for Tower Light Monitoring
applications. It is supplied in an aluminium chassis with an AC power
supply. (Not compatible with the 1701-UC chassis.) Requires a current
sample input from each measured circuit. (Torroid transformer Mdl
12525 recommended.) |
|
| Torroid Sample Transformer (Mdl
12525) |
$ 85.00 |
to index...
Antenna Monitors
1900 Series - FCC ID: IJ3PI1900 |
Description
When compared to previous generation equipment, the 1900 series Antenna
Monitors provide better performance over a wider dynamic range with
virtually no modulation effects. Separate measuring circuits are employed
for each tower. Remote control interfacing is greatly simplified because
these monitors provide simultaneous outputs for the measured Phase
Angle and sample Current Ratio of each tower. Therefore, it is not
necessary for the remote control system to select a specific tower
prior to interrogating a particular telemetry output port. To facilitate
maintenance and system reconfiguration, all active circuits are packaged
on plug-in printed card modules which are accessible at the rear panel
of the monitor. 1900 series Antenna Monitor metering capacity (number
of towers) may be increased or decreased by adding or removing individual
metering modules. |
| 1901 Antenna Monitor
(Two Towers, 1 to 3 Patterns) |
$ 11,330.00 |
| |
Monitor unit with front panel display, local operating
controls, and complete interface capability to remote control systems. |
|
| 1902 Monitor Display |
$ 2,950.00 |
| |
Display Unit for extension manual control and reading
of the 1901 or 1903 Monitors (1-3/4" Panel Height) |
|
| 1903 Antenna Monitor (Two Towers, 1 to 3 Patterns) |
$ 9,560.00 |
| |
Monitor unit with no display or controls, for control
from a Type 1902 Monitor Display, with complete remote control interface. |
|
| 1910 Tower Inputs Metering Board |
$ 1,570.00 |
| |
(1 ea Required for each tower) Circuit Card for one
Tower input. Provides full metering support and outputs for Phase
Ratio and Amplitude for one Tower. |
|
Basic Configurations
|
Number
of Towers
|
1901 |
1903 W/1902 |
| 2 |
$ 11,330.00 |
$ 12,290.00 |
| 3 |
$ 12,900.00 |
$ 13,860.00 |
| 4 |
$ 14,470.00 |
$ 15,430.00 |
| 5 |
$ 16,040.00 |
$ 17.000.00 |
| 6 |
$ 17,610.00 |
$ 18,570.00 |
| 7 |
$ 19,180.00 |
$ 20,140.00 |
| 8 |
$ 20,750.00 |
$ 21,710.00 |
| 9 |
$ 22,320.00 |
$ 23,280.00 |
| 10 |
$ 23,890.00 |
$ 24,850.00 |
| 11 |
$ 25,460.00 |
$ 26,420.00 |
| 12 |
$ 27,030.00 |
$ 27,990.00 |
to index...
Ordering Instructions
A 1901 or 1903 Antenna Monitor consists of a chassis with power supplies
and a control board which can support up to (l2)Type 1910 Tower Input
Metering Boards. The basic unit is supplied with two (2) 1910 Boards.
A four tower array would require two additional l910 Boards for a
total of four l9l0 Tower Inputs. Potomac Instruments will configure
a 1900 series monitor and conduct it's final tests at the station
frequency if the following information is specified at the time of
the order:
|
| Number of Towers |
(2-12) |
________ |
Twrs. |
| Number of Patterns |
(1-3) |
________ |
Pats. |
| Non-Directional Patterns |
|
________ |
Y / N |
| Reference Tower for each Pattern |
|
________ |
D/N/3rd |
| Operating Frequency |
|
________ |
kHz |
| Sampling Line Impedance |
(50 or 75 ohms) |
________ |
ohms |
| Input Connector Type |
(UHF or N) |
________ |
|
| AC Power |
(117, 230, or 245 VAC) |
________ |
VAC |
| AC Frequency |
50 or 60 Hz |
________ |
Hz |
| Special Applications |
 |
To the extent feasible 1900 series antenna monitors can be manufactured
for low signal levels or may incorporate custom filters for applications
involving interference derived from a nearby transmitter facility
or from diplexing more than one frequency onto a single antenna system.
Filters are custom designed, manufactured and certified for each specific
application and are thus considered to be "Custom Engineering Projects."
Potomac Instruments will design, manufacture, and test the filter
performance in the specific Antenna Monitor. Potomac will also certify
that the Antenna Monitor meets or exceeds its original FCC Type Approval
specifications and maintain full records of each system for service
and technical support. In all cases Potomac Instruments will need
to carefully define the design parameters of such filters. Accordingly,
sampling system design and the specifics of the Desired to Undesired
(D/U) signals that appear at the, properly terminated, RF input connectors
of the antenna monitor must be understood. If the diplexed or interfering
signals are already present on the antenna the data necessary for
Potomac to proceed with a design can be obtained by using a Potomac
Instruments' FIM-41 or FIM-21 to measure the relative amplitude of
the desired signal and each of the undesired signals from the sampling
system. Potomac will supply detailed instructions to assist in this
process or the station can utilize a consulting engineer to prepare
the necessary data. |
to index...
| R.F. Generator |
| SD-31 |
High output R.F. Frequency Synthesizer:
covering 100 kHz to 1999.5 kHz in 500 Hz steps |
$ 7,950.00 |
| SD-31 Accessories |
| RX-31 |
Companion receiver for SD-31:
for use in making R.F. bridge measurements |
$ 2,355.00 |
| FL-31 |
Two Pole Tuneable Filter
Useful in any AM application requiring selective tuning. Fused with
Continuous Tuning over AM band, mounted in a shielded Cast Aluminum
Enclosure |
"Special Order Item" |
| HS-11 |
Headset |
$ 40.00 |
| C30042 |
Detector Cable, SD-31 to FIM-41 |
$ 160.00 |
| TEST CABLE |
RG223 Double Shielded Coaxial Cable:
five foot length with BNC male connectors on both ends |
$ 85.00 |
| SOFT CASE |
Padded Soft Carrying Case
Made of 400 Denier Pack Cloth
|
$ 210.00 |
|
|
|